Close Menu
Tactical AmericansTactical Americans
  • Home
  • Guns
  • Knives
  • Gear
  • News
  • Videos
  • Community

Subscribe to Updates

Get the latest tactical, firearms and many more news and updates directly to your inbox.

What's Hot

This Tiny Knife Raised $450,000 in Under a Week

Feb 19, 2026 11:55 am

Bystander Michael Black tackles shooter at Rhode Island hockey game

Feb 19, 2026 11:50 am

Testing Hollywood: Michael Mann’s Collateral

Feb 19, 2026 11:06 am
Facebook X (Twitter) Instagram
Thursday, February 19, 2026 12:13 pm EST
Trending
  • This Tiny Knife Raised $450,000 in Under a Week
  • Bystander Michael Black tackles shooter at Rhode Island hockey game
  • Testing Hollywood: Michael Mann’s Collateral
  • GearPatrol: Two Legendary Outdoor Brands Collab to Upgrade a Camp Classic
  • Analog Cold-Chain Transport: CRO 2U Blood Transport Container
  • 3rd Circuit Upholds NJ Ban on 3D Gun Files
  • Trump task force hits 10,000-arrest milestone in DC crime crackdown
  • HUXWRX and Strider Knives Introduce 50-Unit Military-Spec Black Magic Configuration
  • Privacy
  • Advertise
  • Contact
Facebook X (Twitter) Instagram Pinterest VKontakte
Tactical AmericansTactical Americans
  • Home
  • Guns
  • Knives
  • Gear
  • News
  • Videos
  • Community
Newsletter
Tactical AmericansTactical Americans
Home » Analog Cold-Chain Transport: CRO 2U Blood Transport Container
Gear

Analog Cold-Chain Transport: CRO 2U Blood Transport Container

newsBy newsFeb 19, 2026 10:58 am2 ViewsNo Comments
Facebook Twitter Pinterest LinkedIn Tumblr WhatsApp
Analog Cold-Chain Transport: CRO 2U Blood Transport Container
Share
Facebook Twitter LinkedIn Pinterest Email

CRO has developed a two-unit (2U) whole blood transport container designed to accept multiple Commercial Off-the-Shelf evaporative cooling engines. The system is intended to sustain up to 42 hours of low-titer O whole blood (LTOWB) cooling within transport temperature parameters (-10°C), depending on configuration and operating conditions.

This solution reduces EM signature, provides indefinite non-powered cooling with appropriate consumable resupply, and addresses delayed MEDEVAC during LSCO.

Background

Contemporary large-scale combat indicates that the increased use of unmanned aircraft systems has expanded persistent ISR (intelligence, surveillance, and reconnaissance) coverage and reduced freedom of maneuver across the battlespace. In LSCO (Large-Scale Combat Operations), units should expect extended disruption to communication, increased sustainment friction, and periods of constrained movement due to persistent aerial observation and strike risk.

These conditions intensify requirements for distributed small-unit operations and longer-duration self-sustainment. Contested airspace and massed fires increase the likelihood of delayed evacuation and degraded medical evacuation times. As evacuation timelines extend, casualty outcomes become increasingly dependent on Prolonged Field Care to include reliable cold-chain sustainment for blood products in austere conditions.

Commanders and medical planners should consider cold-chain solutions that reduce reliance on powered systems and provide resilient, low-complexity backup options consistent with DDIL (Denied, Degraded, Intermittent, and Limited) operating conditions.

Indefinite Cooling with Resupply

Commercially available evaporative cooling systems can provide a non-electric (“analog”) cooling method that reduces reliance on batteries and powered refrigeration in constrained environments. Chemical heat sources can drive phase-change and evaporation processes that transfer cooling to a cold plate without active electrical power, enabling extended cooling duration with appropriate consumable resupply.

Approach 

Analog Cold-Chain Transport: CRO 2U Blood Transport Container

Figure 1: Concepting a 2U container with evaporative cooling engines

To integrate evaporative cooling into whole blood transport, we addressed two problems in parallel. First, no Commercial Off-the-Shelf (COTS) blood transport container uses evaporative cooling engines, so we had to develop the container architecture from the ground up. Second, the required form factor is not achievable by simply stripping down two single-unit containers and placing them side-by-side, and legacy GWOT-era medical bags were not designed to carry blood at all. Prior solutions largely relied on retrofitting existing equipment. Our approach was to design the 2U container first, then design a bag purpose-built to accept and retain it. This effort resulted in the CRO DCR 26L– a larger, more capable POI medical bag engineered to integrate the 2U Blood Transport Container (BTC).

Production 

Figure 2: Production Design and foam integration

Design for Manufacturing (DFM) began by establishing baseline dimensions using layered foam prototypes. After completing the initial CAD, we evaluated expanding-foam insulation options and refined the flange geometry to prevent foam spillover during assembly. Once the container profile was finalized, we integrated the evaporative cooling engine retention features into the production design.

Production V1 Design

Figure 3: Production V1

Figure 4: Production V1: 2U BTC

Figure 5. Production V1 with CRO 26L

Other Considerations

EM Signature Reduction

In a contested electromagnetic spectrum, electromagnetic signature management is an increasingly relevant survivability consideration. Common medical and support equipment can produce detectable electromagnetic (EM) emissions through electromagnetic interference and unintentional radiators, even when the equipment is not intended to transmit. Distributed small units should account for these emissions and, where practical, mitigate leakage and reduce reliance on powered systems, while recognizing that many battlefield sensor payloads remain primarily electro-optical/infrared (EO/IR).

Targeting Medical Personnel

Medical personnel have faced an elevated risk of engagement in contemporary conflicts, including documented allegations of targeting by the Armed Forces of the Russian Federation. When only medics carry distinctive medical loadouts, visible differentiation can increase exposure to observation and engagement. By selecting and distributing common carriage systems across the element, units can reduce target indicators that single out medical personnel, as multiple personnel will carry similar bags and mixed-use equipment. Preventing medic casualties preserves morale, maintains continuity of care, and sustains overall unit effectiveness.

For additional technical data, configuration options, or pricing, contact customer support: [email protected]
CRO 2U Blood Transport Container (PN: CRO-2U-MC)

DCR 26L first-line aid bag w/ 2U BTC (Bundle PN: DCR-26L-2U-MC).

MSRP: $920.00


This entry was posted
on Thursday, February 19th, 2026 at 15:00 and is filed under Guest Post, Medical.
You can follow any responses to this entry through the RSS 2.0 feed.

You can skip to the end and leave a response. Pinging is currently not allowed.

Read the full article here

Share. Facebook Twitter Pinterest LinkedIn Tumblr Email

Related Posts

This Tiny Knife Raised $450,000 in Under a Week

HUXWRX and Strider Knives Introduce 50-Unit Military-Spec Black Magic Configuration

Ferro Concepts – GRAB

PenCott GreenZone Returns: Hyde Definition and WidePlus International Relaunch Iconic Camouflage Fabrics at EnforceTac 2026

Fort Benning Integrates Virtual Drone Training into OSUT Program of Instruction

Tisas Arms Corp Begins Georgia Operations

‘Riding Shotgun’ Series Explores the Future of Responsible Off-Highway Adventures

American Tactical Introduces the Calvary 3B Triple Barrel Shotgun

Jam to Music, Chat With Your Crew: POC Obex Connect Ski Helmet Review

Add A Comment
Leave A Reply Cancel Reply

Editors Picks

Bystander Michael Black tackles shooter at Rhode Island hockey game

Feb 19, 2026 11:50 am

Testing Hollywood: Michael Mann’s Collateral

Feb 19, 2026 11:06 am

GearPatrol: Two Legendary Outdoor Brands Collab to Upgrade a Camp Classic

Feb 19, 2026 11:03 am

Analog Cold-Chain Transport: CRO 2U Blood Transport Container

Feb 19, 2026 10:58 am

Subscribe to Updates

Get the latest tactical, firearms and many more news and updates directly to your inbox.

Latest News

3rd Circuit Upholds NJ Ban on 3D Gun Files

By Jack Bogart

Trump task force hits 10,000-arrest milestone in DC crime crackdown

By Jack Bogart

HUXWRX and Strider Knives Introduce 50-Unit Military-Spec Black Magic Configuration

By news
Tactical Americans
Facebook X (Twitter) Instagram Pinterest YouTube
  • Privacy Policy
  • Terms of use
  • Press Release
  • Advertise
  • Contact
Copyright © 2026 Tactical Americans. Created by Sawah Solutions.

Type above and press Enter to search. Press Esc to cancel.